• Search:
News
Fire Rescue Air Cushion 2011-12-06

First, Fire Rescue Air Cushion with caution, so as to not induce jumping. once the fire lay in impact encouraging individuals jumping cushion, that will cause three extremely considerable problems: first, individuals might not inflate within oxygen previous to the jump, and instant impact in the direction of the ground, top to even more considerable injuries; The 2nd is individuals see the oxygen rushed out shortly after the jump, the earliest individuals who start as well previous due to leave the air, individuals who have fallen shortly after the start in the direction of the collision using the last strike of all individuals are jumping concerning the air, resulting in even more considerable injuries ; the 3rd is centered on assessments within soil from 15-20 meters could possibly be the restrict of oxygen escape (about 6 floors or less), and build fire air, you cannot contact for that only the pursuing individuals can start the sixth floor, seventh flooring above the masses if you actually see a comparable oxygen would start concerning the uncomplicated or not be correct on account of impact on oxygen falls and brought about casualties, so totally inappropriate utilization of oxygen rescue fire rescue.

Second, build the fire within oxygen in opposition to the clock slow for emergency. Fire in opposition to the clock, the earliest thought could possibly be the instant institution fighting fires, and rescue trapped people. primarily since the fire escape time is extremely limited (according in the direction of the review space within fire, burning within fire to melt away just 6 mines overall), on this kind of the short time period of time, hold into account the earliest build life-saving oxygen is not useful idea, contact for to wait around for completion of inflatable oxygen cushion time, the oxygen is as well light, once the inflation is complete, uncomplicated flowing, the complete treatment a lowest of 5 individuals simultaneously, jointly using the required fire dispatch time, no time. So we contact for to caution oxygen rescue, do not final result in individuals to wait around using the laying of air, while the delay time to escape, but even more considerable injuries. In addition, when individuals jump, the present prison buildings, complete of affordable limitations of space, oxygen masses could be accurately fall on it? Thus, the present in a really quickly altering fire commanders to retain an obvious head, dimension up the situation, a sensible ask of fire-fighting tactics, correct hold out the part of life-saving models just like air.

Third, we will require to conscientiously doing amazing occupation oxygen of regime maintenance, and inspection. August 29, 2006, Ministry of online community protection specialized Oversight Committee authorized the discharge GA631-2006 "Fire rescue oxygen cushion" cushion is divided into common sort fire rescue fire rescue fire rescue cylindrical oxygen cushion gas. "Fire Rescue Air Cushion" common offers fire rescue oxygen cushion models, specialized requirements, look at methods, using storage, regime inspection and screening rules. Since the Fire Rescue Air Cushion specialty products, the common obviously states it’s only for emergency rescue and fire forces without any other option method to use, relief height should certainly not exceed 16 meters. Inflation must turn out to be checked just about every three weeks away from time, with fifty kilograms of sandbags from twelve meters in height three occasions operating look at in non-routine inspections over the office staff jump. Therefore, the fire fighters within common inspection, upkeep is vital to run in rigid accordance using the above requirements, should not be careless, top to an accident.

Copyright © 2010-2012 Taizhou Lion King Signal Co., Ltd
Internet Marketing By Netcec&Bossgoo Link